Heeler RV Electrical

HEELER RV ELECTRICAL · OWNER REFERENCE EXAMPLE

JAYCO TALON
ELECTRICAL SYSTEM OWNER REFERENCE

A practical record of the major electrical equipment in this trailer, how the AGM battery bank is charged and used, sensible future upgrade paths, and a repeatable long-term storage procedure.

House battery12 V / 240 Ah AGM
Roof solar~380 W
Converter60 A
Generator5.5 kW
Independent reference: This is a Heeler RV Electrical owner reference prepared from the equipment and wiring present on one Jayco Talon trailer. It is not a Jayco factory manual and is not affiliated with or endorsed by Jayco, Inc. Manufacturer documentation and equipment instructions remain the authority for factory specifications and safety requirements.

1. What is installed

ComponentMake / modelOwner-relevant specification
House battery bankTrojan T105-AES2 × 6 V, 240 Ah batteries wired in series for 12 V / 240 Ah
Converter / chargerProgressive Dynamics PD4560K18NS2B60 A; Charge Wizard profile: 14.4 V / 13.6 V / 13.2 V
GeneratorCummins Onan 5.5HGJAB-6755L5.5 kW; starts from the house battery bank
Roof solar panel 1Go Power GP-PV-190M190 W
Roof solar panel 2Canadian SolarApprox. 190 W; exact model not recorded
Total roof solarTwo-panel arrayApprox. 380 W total
Solar charge controllerMC2450N10 MPPT50 A; 12/24 V; up to 660 W PV on a 12 V battery system
Solar remote displayRM-6 Remote MeterDisplays solar-controller and battery information
Trailer control systemBMPRO RVMN101A RVGeniusNode / JAYCOMMANDTrailer control node
Tow-vehicle chargingOEM 7-way charge circuitSupplemental charging while travelling
AC source transferOEM automatic transfer systemSelects shore power or generator power
Battery monitor on handRenogy battery monitor / shunt kitNot presently installed
Factory red-key switch

The exterior switch is labelled “Battery Disconnect,” but the OEM wiring diagram shows that it is not a complete battery-bank disconnect. It turns off designated switched loads while several constant battery circuits remain energized.

Owner note: turning the red-key switch OFF does not mean the house batteries are electrically isolated from the trailer. This matters during long-term storage.

2. Battery upgrade and how to use it

Trojan T105-AES battery bank

The original 6 V flooded lead-acid batteries were replaced with two Trojan T105-AES sealed AGM deep-cycle batteries. The bank keeps the trailer's original 12 V architecture while providing a lower-maintenance deep-cycle battery system.

  • No routine watering or electrolyte maintenance.
  • Designed for repeated deep cycling and partial-state-of-charge use.
  • Compatible with conventional AGM charging equipment when the charge profile is set correctly.

How much of the battery should be used?

These batteries can tolerate deeper cycling better than ordinary AGM batteries, but they should not be treated like lithium batteries with a routine 0%-to-100% usable window. Shallower cycling generally supports longer service life.

Monitor SOCApprox. Ah remainingMeaningPractical action
100%240 AhFully chargedNormal starting point
75%180 AhLight dischargeNo concern
50%120 AhAbout half the bank usedGood routine recharge point
30%72 AhDeep dischargeRecharge soon
20%48 Ah80% depth of dischargeTreat as practical minimum; recharge promptly
0%0 AhFully dischargedAvoid as a normal operating target
Simple rule

For normal RV use, plan around 50% SOC as a sensible routine recharge point. An occasional deeper discharge is not automatically harmful to Trojan AES AGM batteries, but do not intentionally run the bank below about 20% SOC or leave it deeply discharged.

Converter / charger match

The existing Progressive Dynamics 60 A converter is a practical match for the Trojan bank. Its main charge voltages are close to Trojan's AGM targets, so the converter does not need to be replaced simply because the batteries were upgraded.

FunctionTrojan AES targetExisting PD4560
Main / absorption charge14.4 V14.4 V Boost
Float / normal chargingApprox. 13.5 V13.6 V Normal
Long-term maintenanceLow maintenance voltage13.2 V Storage

Solar controller profile

The MC2450N10 controller should be checked for the Trojan AGM bank. A suitable user-defined profile uses about 14.4 V boost/absorption, about 13.5 V float, and automatic equalization OFF. Confirm current manufacturer guidance before changing settings.

3. Logical future improvements

Before adding equipment, first identify the actual limitation: not enough stored energy, not enough charging, or a need for more 120 V power.

  1. Install the battery monitor / shunt. A correctly configured shunt sees current entering and leaving the whole battery bank and provides a much better fuel-gauge view than solar-controller information alone.
  2. Add a proper solar disconnect. A clearly labelled, properly DC-rated 2-pole PV disconnect on the solar-input side of the MC2450N10 improves serviceability and storage testing.
  3. Add solar if charging recovery is the problem. The existing array is about 380 W and the controller is rated for up to 660 W on a 12 V system. Additional panel capacity is possible subject to confirming panel compatibility, wiring and protection.
  4. Add battery capacity if stored energy is the problem. A second matched pair of T105-AES batteries could increase the bank to approximately 12 V / 480 Ah. Additional batteries are best planned while the original pair is still relatively new.
  5. Add an inverter only for a defined 120 V need. Significant inverter loads should be planned together with battery capacity, conductor size and overcurrent protection.

4. Long-term storage procedure

Because the red-key switch does not fully disconnect the battery bank, long-term storage should include an actual current check rather than assuming the batteries are isolated.

Fully charge the batteries

Plug the trailer into shore power and allow the Progressive Dynamics converter to complete the charge. Overnight or about 24 hours is a practical preparation period. The goal is a fully charged bank, not simply a fixed number of hours.

Remove charging sources

Unplug shore power, disconnect the tow vehicle and make sure the generator is off. Solar must also be removed from the test. Use a proper PV disconnect if installed, otherwise perform the current test after dark or safely isolate the identified PV circuit.

Turn the factory red-key switch OFF

Use the trailer's normal storage-switch position. Remember that constant B+ circuits remain connected even with this switch off.

Let the electronics settle

Wait about 5 minutes so control modules can enter their normal standby state.

Measure storage current

Preferred method: read a correctly installed shunt. Alternate method: use a low-current-capable DC clamp meter at an appropriate series-bank conductor where no midpoint loads are present.

Check the bank during storage

For storage lasting several months, check battery condition periodically. Trojan guidance should be consulted for the current recharge threshold and storage interval. Do not assume solar is maintaining the bank unless solar operation has been verified.

Storage-current guide

Continuous drawUse in 90 daysOwner guidance
5 mA10.8 AhExcellent
10 mA21.6 AhVery good
20 mA43.2 AhInvestigate if practical
50 mA108 AhToo high for unattended long-term storage

Target: storage current should be as close to zero as practical. Around 10 mA or less is excellent. If measured draw is above about 20 mA, identify what remains energized before leaving the trailer for several months.

Storage SOC checkpoints

Approx. SOCRested 12 V bank voltageMeaning
100%12.84 VFully charged
75%12.54 VRecharge point during storage
50%12.24 VToo low to leave sitting
20%Approx. 11.9 V regionDeeply discharged - recharge promptly

Voltage-based SOC should be checked after the batteries have rested with charging and significant loads removed. A correctly configured shunt is the better day-to-day SOC indicator.

Owner summary

This trailer uses a 12 V / 240 Ah Trojan AES AGM house bank supported by a 60 A Progressive Dynamics converter, approximately 380 W of rooftop solar, the existing 50 A MPPT controller, the Onan generator and supplemental tow-vehicle charging. It can remain a conventional AGM system and still provide a capable, serviceable RV power setup.

  • Best first improvement: install and configure the battery monitor / shunt.
  • Best serviceability improvement: add a proper PV solar disconnect.
  • Add solar if recharge time is the limitation.
  • Add another matched Trojan pair if stored energy is the limitation.
  • Consider an inverter only when there is a defined off-grid 120 V requirement.

Future changes should be checked against the actual equipment, conductor sizes, fuse/breaker protection, battery condition and installation layout present at the time of the work.

Want a reference built around your RV?

Heeler RV can review the actual battery, charging, solar and distribution system and leave you with a practical owner reference instead of a mystery bundle of wires and unlabeled equipment.